Although provided as a guide only common sense and job specific detailing can be added by qualified designers.
Garage door head flashing detail nz.
Acceptable solution e2 as1 to building code clause e2 external moisture is quite prescriptive in terms of head flashing profile when used as a means of compliance.
Stostucco construction system flashman head flashing ss 878.
The requirements for flashing garage door openings are simple.
As nzs 4284 tested using flashmans flashing system in conjunction with flashclad s cladding systems.
Find a range of cad drawings here.
For more information visit www marley co nz or phone 0800 marley 0800 627 539 e z e r e w e uv resistant figure 5 figure 6 figure 3 figure 4 door trim saw cut for flashing brick veneer ramp to door weephole lining door.
Figure 2 garage door head detail with direct fixed bevel back horizontal weatherboard cladding.
James hardie cad library provides you with a range of cad drawings that can be used in your design detailing.
For this reason the 0 9 mm limit should apply in all situations.
The information and technical details provided correlate with all legislative requirements and generally accepted good trade practice.
Our test was conducted without the reliance on sealants foams or plastic back flashings achieving 4 500 kpa 312 kph wind speeds.
Wall underlay turned in to door opening with flexible flashing tape to corners flexible flashing tape to head flashing upstand or additional layer of underlay lintel head flashing with 15 slope 35 mm minimum flashing lap under cladding increase to 60 mm.
Getting the garage door jamb detail right for brick veneer can be tricky.
A drainage and ventilation gap of 5 mm must be left between the bottom of the cladding above the flashing and the top of the sloped flashing.
They are the same as for external door and window details.
Acceptable solution e2 as1 to building code clause e2 external moisture is quite prescriptive in terms of head flashing profile when used as a means of compliance.
However wider overhangs are prone to deformation or flutter in higher winds.
Many new houses include an attached garage.
Head flashing a metal head flashing with a 15 slope is installed against the wall underlay and over the window frame to provide 10 mm cover to the face of the window frame.
Www accumen co nz lightweight exterior decorative moldings and shapes including columns architraves.