Loose electrical cables there could be loose electrical cables inside the circuit box or somewhere in your ac which could be causing a short circuit.
Furnace blows fuse on circuit board.
Make sure there is not chafed wires.
Your furnace s control board has a separate fuse that protects it from getting too hot.
First the bad.
Furnace blowing cold air.
If the fuse blows when you have no low voltage wires hooked to the furnace then you have an internal problem like a bad limit gas valve connection or control board.
Remove the service panel on the goodman unit 5 16 screws where the power comes in.
If someone is poking around your furnace and is not too careful they could more wires so that they come into contact with the furnace s wire frame causing them to short and blow the fuse on the furnace board.
If the fuse keeps popping in your air conditioner you have a 24 volt short.
You need to find the root cause of the blown fuse on the furnace circuit board before you cause damage to the unit.
I ve removed low voltage wires coming from thermostat and ac unit and i ve removed the 9 pin connector for the 24 volt circuit within the furnace.
The good news and bad news about electric furnace troubleshooting.
Here s how to diagnose a low voltage short.
It isn t the hsi inducer or blower motor as these are all high voltage parts not low voltage.
Last guy replaced board already.
So i m working on a sure comfort nat gas furnace.
The most probable of these are 1.
Apparently theres been somebody else here already.
Check out this post.
This was done after i couldn t get an appointment soon enough for a.
Amperage draw anything near the fuse rating would periodically blow a fuse.
This is one of the most common reasons why the furnace fuse is blown.
Or just throw parts at it.
After resetting the circuit breaker and replacing the fuse if the fuse keeps blowing there might be an electrical short in the electrical system that supplies the electricity to the furnace.
Within a 1 5 secs after i push door switch in the 3 amp fuse blows.
The furnace requires a lot of electricity to run and your home may not have the means to support it or there could be a short in the system.
Diy and save 300 500.
The coil in the contractor is 24v.
There could be several reasons why air conditioner keeps blowing fuse in circuit board.
If that all check out.
Is your furnace running but blowing cold air.
Here are a few of the most common problems.
Sometimes the blown fuse in the furnace comes from a malfunctioning transformer.
The contractor may be hanging up or shorting.